+86-21-35324169

Isingeniso Lesi sixazululo sakhiwe ngokuzungeza umqondo wesikhungo sedatha yemojula encane, ehlanganisa ndawonye ingqalasizinda eyinhloko njengama-server rack, ukugcinwa kwephasishi, ukupholisa okunembayo, i-UPS nokusatshalaliswa kwamandla, ukuqapha indawo ezungezile, nokuvikelwa kwezokuphepha. Idizayini ye-modular ivumela i-conf eguquguqukayo ...
Lesi sixazululo sakhelwe eduze komqondo wesikhungo sedatha yemojula encane, ehlanganisa ingqalasizinda eyinhloko njengama-server rack, ukugcinwa kwe-isle, ukupholisa okunembayo, i-UPS nokusatshalaliswa kwamandla, ukuqapha kwemvelo, nokuvikelwa kwezokuphepha. Idizayini ye-modular ivumela ukucushwa okuguquguqukayo okusekelwe ezidingweni zamakhasimende-okuhlanganisa ukuminyana kwamandla, isikali semishini ye-IT, izinga lokutholakala, kanye nezinhloso ze-PUE-ukuletha indawo enokwethenjelwa neyingozi yokusebenza kwe-IT.
(1) Amamojula Okupholisa Omugqa - Ibanga Lomthamo Obanzi
● Ibanga Lamandla: 5–90 kVA
Inikeza izinketho zokupholisa eziningi kunabathengisi abaningi emakethe.
● Izinsimbi ze-Premium
Yakhiwe ngezingxenye ezivela kumabhrendi ahamba phambili emhlabeni wonke ukuze kuqinisekiswe ukwethembeka kwesikhathi eside.
● Ukupholisa Okuluhlaza Okusebenza Kakhulu
- I-Inverter compressor, abalandeli be-EC kanye neziqandisi ezinobungani bemvelo
- Uhlelo lokulawula oluhlakaniphile
- Ukupholisa kwamahhala okusizwa ngephampu ukuze wonge amandla angeziwe
● Izinketho Zokwenza ngokwezifiso
Ukujula: 1100/1200 mm
- Ukuphuma komoya ngaphambili noma eceleni
- Ama-air baffles alungisekayo
(2) Uhlelo lwe-UPS Olwenzelwe I-Rack Ye-MDC
● Ibanga Lamandla Eliphelele: 3–600 kVA
- 230V1P | 400V3P: 3–200 kVA
- 240V2P | 208V3P: 6–150 kVA
– 480V3P: 80–400 kVA
● I-Rack-Ready Design
Amamojula e-UPS asuka ku-3–200 kVA asekela ukufakwa okuqondile kwama-rack.
● Ukusebenza Okusebenza Kakhulu
- Kufika ku-96% ukusebenza kahle kwimodi ye-inthanethi
- Kufika ku-99% kumodi ye-ECO
● High Power Factor
Okuphumayo kwe-PF kufika ku-1.0 ukuze uthole amandla aphezulu asebenzisekayo.
(3) Ukuqapha Nokuphatha Okuhlakaniphile
● Umsingathi Wokuqapha Ohlanganisiwe
Inkundla eyodwa yokuphatha ukufinyelela nokuqapha uhlelo.
● Izinketho Zokubonisa
10", 21" no-43" osayizi besikrini kuye ngezidingo zephrojekthi.
● Ukuqapha Okuphelele
Kufaka phakathi amandla, ukupholisa, izinga lokushisa, umswakama, ukuvuza nesimo sokufinyelela.
Isekela ukucushwa okukude nge-DCIM, njengamapharamitha wokupholisa nokulawula umnyango.
● Vula Ukuhlanganiswa
Ihambisana ne-UPS, amajeneretha, amakhamera nezinye izinto zokusebenza zezinkampani zangaphandle.
Isekela ukuhlanganiswa ku-BMS emaphakathi.
(4) IT Rack System
● Umthamo Ophakeme Wokulayisha
Uhlaka oluqinisiwe olusekela kufika ku-1800 kg.
● Izinketho zikasayizi
Ububanzi: 600/800 mm
Ukujula: 1100/1200 mm
- Ukuphakama: 42U / 45U / 48U
● Izinketho Zokulawula Ukufinyelela
– Mechanical key lock
- Ilokhi ye-elektroniki ye-RFID
– 3-in-1 smart lock
– Ukuvuleka nokuqapha komnyango kude
● Izinsiza Ezicebile
Kufaka amaphaneli aseceleni, amaphaneli angenalutho, imichilo yebhulashi, okokufaka uphawu nokuphathwa kwekhebula okuphelele (evundlile, eqondile, phezulu).
| Imodeli | Amapharamitha |
| 60R | Amakhabethe: amayunithi ayi-14 UPS: 60kVA (kW) Ukupholisa: 51.2+51.2kW Ukusatshalaliswa kwamandla: 250A/380V Okudingekayo:N+1 |
| 100R | Amakhabethe: amayunithi angama-22 I-UPS: 90kVA (kW) Ukupholisa: 25.1* (3+1) kW Ukusatshalaliswa kwamandla: 320A/380V Okudingekayo:N+1 |
| 120R | Amakhabethe: amayunithi angama-28 I-UPS: 120kVA (kW) Ukupholisa:40.9*(3+1)kW Ukusatshalaliswa kwamandla: 400A/380V Okudingekayo:N+1 |
| 150R | Amakhabethe: amayunithi angama-36 I-UPS: 150kVA (kW) Ukupholisa: 25.1* (5+1) kW Ukusatshalaliswa kwamandla: 500A/380V Okudingekayo:N+1 |
| Ukwenza ngokwezifiso | Amakhabhinethi: Ngaphansi kwamayunithi angama-48 UPS: ≤500kVA (kW) Ukupholisa:Kwenziwe ngokwezifiso ngokufunwa Ukusabalalisa Amandla: Okuyisisekelo, Okuhlakaniphile Okungadingeki:N/N+1/2N |
(1) Ukuphumelela Kwamandla Okuthuthukisiwe
● Ukupholisa kwamahhala okusizwa ngephampu ngokungaqondile ukuze kwenziwe ngcono ukusebenza.
● Ukubamba indawo kunciphisa ukuxubana komoya oshisayo/obandayo futhi kunciphisa ukulahleka kwamandla.
● Izingxenye ezisebenza kahle kakhulu ezihlanganisa i-inverter compressors, abalandeli be-EC namafriji aluhlaza.
● Ukuqapha kwe-PUE yesikhathi sangempela.
● I-UPS isekela imodi ye-ECO yokonga amandla okwengeziwe.
(2) Ukuphatha Okumisiwe Nokwenziwa Lula
● Idizayini ye-modular, yesitayela se-LEGO yokuphindaphinda okusheshayo nokusetshenziswa.
● Ukuqapha kwendawo nokukude ukuze ubone ngeso lengqondo kalula nokulawula.
● Ama-alamu esikhathi sangempela nezaziso zokusebenza okuzinzile.
● Ukuthengwa kwezinto, ukufakwa kanye nokugcinwa lula ngokusebenzisa imiklamo eyenziwe ngaphambilini.
(3) Ukuvikelwa Kwezokuphepha Okudidiyelwe
● Ihambisana nezidingo zokuklama ze-Uptime Tier I-IV.
● Ukulawulwa kokufinyelela okuvikelekile kumnyango ngamunye nerack.
● Ukuxhumana okuzenzakalelayo kokuvikela umlilo okunamaphaneli aphezulu namayunithi okupholisa.
● Ukubhekwa kwevidiyo ngokubuka bukhoma nokwenza isipele sokurekhoda.