+86-21-35324169

Isingeniso Isixazululo sesikhungo sedatha esineziqukathi sakhiwe kusetshenziswa indlela eyakhiwe ngaphambili, lapho isiqukathi sisebenza njengendawo evalekile yazo zonke izinhlelo zesikhungo sedatha. Ingqalasizinda eyinhloko-okuhlanganisa ama-rack e-IT, izinhlelo ze-UPS, ukupholisa okunembayo, ukusatshalaliswa kwamandla, izinkundla zokuqapha, kanye nesakhiwo...
Isixazululo sesikhungo sedatha esineziqukathi sakhiwe kusetshenziswa indlela eyakhiwe ngaphambili, lapho isiqukathi sisebenza njengendawo evalekile yazo zonke izinhlelo zesikhungo sedatha. Ingqalasizinda eyinhloko—okuhlanganisa ama-rack e-IT, amasistimu e-UPS, ukupholisa okunembayo, ukusatshalaliswa kwamandla, amapulatifomu okuqapha, kanye nekhebula ehlelekile—ihlanganiswa kusengaphambili futhi ihlolwe efektri, okuvumela ukulethwa kwe-one-stop yangempela. Lokhu kunciphisa kakhulu umsebenzi wokwakha endaweni futhi kusekela ukukhishwa kwesevisi okusheshayo.
Idizayini ivumela ukwenza ngokwezifiso okubanzi okusekelwe ezidingweni zeklayenti futhi ingakwazi ukuzivumelanisa nezimo ezihlukahlukene zohlelo lokusebenza olukhethekile.
● Ubunjiniyela Obungokwezifiso
Sisekelwa i-R&D eqinile namandla okukhiqiza, sihlinzeka ngezikhungo zedatha yeziqukathi ezenziwe ngezifiso kakhulu. Izinketho zifaka amaleveli okutholakala kwesistimu, amabanga okuvikela, ubukhulu besiqukathi, amazinga wamandla, izindlela zokupholisa, nezinye izidingo zobuchwepheshe ezikhethekile.
● Ukuthunyelwa Okusheshayo
Wonke amasistimu angaphansi abalulekile—UPS & ukusatshalaliswa kwamandla, amayunithi okupholisa, ama-IT rack, nezintambo—kuhlanganiswe ngokugcwele ngaphakathi kwesiqukathi ngaphambi kokulethwa. Njengoba zonke izingxenye zilungiswa futhi zihlolwe kusenesikhathi, ukufakwa endaweni kuba lula, okuvumela ukulethwa kwephrojekthi esikhathini esingangezinsuku ezingama-40.
● Ukuphepha Okuphezulu Nokuthembeka
Iziqukathi ezijwayelekile zinikeza ukuvikelwa kwe-IP55, ngezinketho zokuthuthukela ku-IP65. Izithuthukisi ezengeziwe zihlanganisa ukwelashwa okunqanda ukugqwala, ukumelana nomlilo, ukuvikela ukuqhuma, nokuvikela i-ballistic. Ukucisha umlilo okwakhelwe ngaphakathi, ukulawula ukufinyelela, nokuvikela ukuqapha kwevidiyo ezingozini zomlilo, ukweba, nokufinyelela okungagunyaziwe.
● Ukusebenza Okuqhubekayo
Ngokuvikelwa kwemvelo okuqinile kanye nemiklamo etholakalayo ephezulu kokubili amandla kanye nezinhlelo zokupholisa, isixazululo siqinisekisa ukusebenza okuzinzile nokungaphazamiseki kwezinhlelo zebhizinisi ezibaluleke kakhulu kumishini.
| Konke ku-One Solution | |||
| 10ft iKhabhinethi | 20ft iKhabhinethi | 40ft iKhabhinethi | Amakhabhinethi e-Modular Custom |
![]() | ![]() | ![]() | ![]() |
| Isixazululo se-Dual Bay | |||
![]() | |||
| Isixazululo se-Multi Containers | |||
![]() | |||
(1) Ukwakhiwa Kwesitsha
● Yenzelwe izindinganiso zesiqukathi se-ISO
● Ukumelana nesifutho sikasawoti: amahora angu-750
● I-rock wool i-thermal insulation
● Imelana nesivinini somoya esingafika ku-30 m/s
● Izinketho zokumelana nomlilo kufika emaminithini angu-120
● Ukuvikelwa okungakhethwa kwe-ballistic kumasayithi avikeleke kakhulu
● I-C5M ukumelana nokugqwala kwezindawo ezisogwini
● IP55 ukuvikela uthuli namanzi
● Izinga lokushisa lokusebenza: -40°C kuya ku-+55°C
(2) Uhlelo Lokupholisa Olunembile
● 5–31.5 kW ukupholisa odongeni (okujwayelekile)
● 6–90 kW izinketho zokupholisa ezisemgqeni
● Izinketho zokupholisa zegumbi 5–122.9 kW
● Ifanele amazinga okushisa afika ku-55°C
● Izilungiselelo zokupholisa mahhala ezitholakalayo
(3) IT Rack System
● 1800 kg umthamo wokulayisha omile
● 600/800 mm ububanzi; 1100/1200 mm izinketho zokujula
● Ukuzikhethela kwendawo yokubeka eshisayo/ebandayo
● Ama-rails aphambili/angemuva ukuze alungiswe kalula
● Ukulawulwa kokufinyelela ongakukhetha ukuze uthole ukuvikeleka okuthuthukisiwe
(4) Uhlelo lwamandla lwe-UPS
● 3–60 kVA i-UPS efakwe i-rack
● 60–200 kVA Modular UPS (i-rack mount)
● 250–600 kVA i-UPS yemojuli (ukukhweza phansi)
● Izilungisi ze-VDC ezingu-48 (60 A–1200 A)
● I-VRLA noma ukulungiselelwa kwebhethri ye-lithium-ion
● Izinketho eziyisisekelo noma ezihlakaniphile ze-PDU
● Ukusabalalisa kwamandla akhelwe ngaphakathi enzelwe amazinga esikhathi sokuphumula eSigaba I–IV
(5) Uhlelo lwe-DCIM
● Ukuxhumana okuhlanganisiwe ne-UPS, ukupholisa, amamojula wamandla, nezinzwa
● Ukulawulwa kokufinyelela okuhlanganisiwe
● Ukubhekwa kwevidiyo okudidiyelwe
● Isixhumi esibonakalayo sesikrini esithintwayo sasendaweni (10/21/42 amayintshi)
● Ukufinyelela kude ngewebhu, i-SMS, i-imeyili, i-Modbus-TCP; i-SNMP yokuzikhethela
(6) Uhlelo Lokulawula Ukufinyelela
● IP55 indlela yokufinyelela emithathu-kokukodwa: Iphinikhodi / iphasiwedi / izigxivizo zeminwe
● Ukuphathwa kwesofthiwe ezimele
● Ihlanganiswe ngokugcwele neplathifomu ye-DCIM
(7) Uhlelo Lokuvikela Umlilo
● Ukutholwa komlilo okuyisixwayiso kusenesikhathi
● Iphaneli yomlilo ehlakaniphile yokuphatha okwenziwe lula
● Izinketho ze-ejenti yokucindezela umlilo: I-Novec 1230 noma i-FM200
● Akwazi ukumelana namanzi futhi angenwa amanzi
● Ukuvikela isifutho sikasawoti
● Ukuvimbela isikhunta
● Ukufakwa komlilo nokushisa
● Ukuvikelwa kokuzamazama komhlaba
● Amandla okumelana nokweba kanye nokumelana nokuqhuma