+86-21-35324169

Intshayelelo Esi sisombululo sakhiwe malunga ne-micro-module data center concept, idibanisa iziseko eziphambili ezifana ne-server racks, i-aisle containment, ukupholisa ngokuchanekileyo, i-UPS kunye nokuhanjiswa kwamandla, ukubeka iliso kokusingqongileyo kunye nokukhuselwa kokhuseleko. Uyilo lwemodyuli luvumela ukuguquguquka kweconf...
Esi sisombululo sakhiwe malunga ne-micro-module data center concept, idibanisa iziseko eziphambili ezifana ne-server racks, i-aisle containment, ukupholisa ngokuchanekileyo, i-UPS kunye nokuhanjiswa kwamandla, ukubeka iliso kokusingqongileyo kunye nokukhuselwa kokhuseleko. Uyilo lwemodyuli luvumela ukucwangciswa okuguquguqukayo okusekelwe kwiimfuno zabathengi-kubandakanya ubuninzi bamandla, isikali sezixhobo ze-IT, inqanaba lokufumaneka, kunye neethagethi ze-PUE-ukuhambisa indawo ethembekileyo kunye ne-scalable yemisebenzi ye-IT.
(1) Iimodyuli zokupholisa ze-Inrow - Uluhlu olubanzi lweZakhono
● Uluhlu loMmandla: 5–90 kVA
Ibonelela ngeendlela zokupholisa ngakumbi kunabathengisi abaninzi kwimarike.
● Amalungu ePremium
Yakhelwe ngeenxalenye ezivela kwiimpawu eziphambili zehlabathi ukuqinisekisa ukuthembeka kwexesha elide.
● Ukupholisa okuLuhlaza okuFanelekileyo
-Iinverter compressors, abalandeli be-EC kunye neefriji ezinobuhlobo kunye ne-eco-friendly
–Inkqubo yokulawula ekrelekrele
-Impompo encediswa ngokungathanga ngqo ukupholisa simahla ukonga amandla ongezelelweyo
● Ukhetho Lwenu
– Ubunzulu: 1100 / 1200 mm
– Ukukhutshwa komoya ngaphambili okanye ecaleni
-Iziphazamiso zomoya ezilungelelanisiweyo
(2) IRack-Optimized UPS System yeMDC
● Uluhlu lwaMandla aPheleleyo: 3–600 kVA
– 230V1P | 400V3P: 3-200 kVA
– 240V2P | 208V3P: 6–150 kVA
– 480V3P: 80–400 kVA
● I-Rack-Ready Design
Iimodyuli ze-UPS ezivela kwi-3-200 kVA zixhasa ukufakwa kwe-rack ngqo.
● Ukusebenza ngokuFanelekileyo
Ukuya kuthi ga kwi-96% yokusebenza kakuhle kwimowudi ye-intanethi
Ukuya kuthi ga kwi-99% kwimodi ye-ECO
● High Power Factor
Imveliso ye-PF ukuya kuthi ga kwi-1.0 kumandla aphezulu asebenzisekayo.
(3) UkuBeka esweni ngoBuchule kunye noLawulo
● Umamkeli oManyeneyo wokubeka iliso
Iqonga elibekwe kumbindi wokulawula ulawulo lofikelelo kunye nokubeka iliso kwinkqubo.
● Iinketho zokubonisa
10", 21" kunye ne-43" ubukhulu besikrini ngokuxhomekeke kwiimfuno zeprojekthi.
● Ukubek' esweni okuBanzi
Kubandakanya amandla, ukupholisa, ubushushu, ukufuma, ukuvuza kunye nesimo sokufikelela.
Ixhasa uqwalaselo olukude nge-DCIM, njengeeparamitha zokupholisa kunye nolawulo lomnyango.
● Vula ukudityaniswa
Iyahambelana ne-UPS, iijeneretha, iikhamera kunye nezinye izixhobo zomntu wesithathu.
Ixhasa ukuhlanganiswa kwi-BMS esembindini.
(4) IT Rack System
● Umthamo ophezulu womthwalo
Isakhelo esomeleziweyo esixhasa ukuya kuthi ga kwi-1800 kg.
● Ukhetho lobungakanani
– Ububanzi: 600/800 mm
– Ubunzulu: 1100 / 1200 mm
– Ubude: 42U / 45U / 48U
● Fikelela kwiiKhetho zoLawulo
– Mechanical key lock
-I-RFID yokutshixa ngombane
– 3-in-1 smart lock
– Ukuvulwa kocango olukude kunye nokubeka iliso
● Izincedisi ezityebileyo
Kubandakanya iipaneli zecala, iipaneli ezingenanto, iibrashi zebrashi, izixhobo zokutywina kunye nolawulo olupheleleyo lwekhebula (horizontal, nkqo, phezulu).
| Umzekelo | Iiparamitha |
| 60R | Iikhabhinethi: iiyunithi ezili-14 UPS: 60kVA (kW) Ukupholisa: 51.2+51.2kW Ukuhanjiswa kwamandla: 250A/380V UkuNgafuneki:N+1 |
| I-100R | Iikhabhinethi: iiyunithi ezingama-22 UPS: 90kVA (kW) Ukupholisa:25.1*(3+1)kW Ukuhanjiswa kwamandla: 320A/380V UkuNgafuneki:N+1 |
| 120R | Iikhabhinethi: iiyunithi ezingama-28 UPS: 120kVA (kW) Ukupholisa:40.9*(3+1)kW Ukuhanjiswa kwamandla: 400A/380V UkuNgafuneki:N+1 |
| 150R | Iikhabhinethi: iiyunithi ezingama-36 UPS: 150kVA (kW) Ukupholisa:25.1*(5+1)kW Ukuhanjiswa kwamandla: 500A/380V UkuNgafuneki:N+1 |
| Ukwenza ngokwezifiso | Iikhabhinethi:Ngaphantsi kweeyunithi ezingama-48 UPS: ≤500kVA (kW) Ukupholisa:Yenzelwe ngokwemfuno Ukusasazwa kwamandla: Esisiseko, ekrelekrele UkuNgafuneki:N/N+1/2N |
(1) Ukomelezwa kokuSebenza kwaMandla
● Ukupholisa okungathanga ngqo okuncediswa yimpompo kuphuculo lokusebenza.
● Ukuvalelwa kwendlela kunciphisa ukuxubana komoya oshushu/obandayo kwaye kunciphisa ukulahleka kwamandla.
● Amacandelo aphezulu kakhulu aquka i-inverter compressors, abalandeli be-EC kunye neefriji eziluhlaza.
● Ixesha langempela lokujongwa kwe-PUE.
● I-UPS ixhasa imo ye-ECO yokonga amandla okongeziweyo.
(2) Ulawulo olusemgangathweni kunye nolwenziwe lula
● Imodyuli, uyilo lwesitayile se-LEGO sokuphindaphinda ngokukhawuleza kunye nokusasazwa.
● Ukubeka iliso kwasekhaya kunye nokude ukuze kube lula ukubonwa kunye nokulawula.
● Iialamu zexesha langempela kunye nezaziso zokusebenza okuzinzileyo.
● Ukuthengwa kwezinto lula, ukufakwa kunye nokugcinwa kwezinto ngokuyilwa kwangaphambili.
(3) UkuKhuselwa koKhuseleko oluDityanisiweyo
● Iyahambelana neemfuno zoyilo ze-Uptime Tier I-IV.
● Ulawulo olukhuselekileyo lokufikelela kumnyango ngamnye kunye nerack.
● Unxibelelwano oluzenzekelayo lokukhusela umlilo kunye neepaneli eziphezulu kunye neeyunithi zokupholisa.
● Ukujongwa kwevidiyo ngombono ophilayo kunye nokurekhoda ukurekhoda.