+86-21-35324169

Intshayelelo Isisombululo seziko ledatha yekhonteyina sakhiwe kusetyenziswa indlela elungiselelwe ngaphambili, apho isikhongozeli sisebenza njengendawo ebiyelweyo kuzo zonke iinkqubo zamaziko edatha. Iziseko zophuhliso ezingundoqo-kubandakanywa iirakhi ze-IT, iinkqubo ze-UPS, ukupholisa ngokuchanekileyo, ukuhanjiswa kwamandla, amaqonga okubeka iliso, kunye nesakhiwo ...
Isisombululo seziko leenkcukacha zekhonteyina sakhiwe kusetyenziswa indlela elungiselelwe ngaphambili, apho isitya sisebenza njengeyona ndawo ibalulekileyo kuzo zonke iinkqubo zamaziko edatha. Iziseko zophuhliso ezingundoqo-kubandakanywa ii-racks ze-IT, iinkqubo ze-UPS, ukupholisa ngokuchanekileyo, ukuhanjiswa kwamandla, iiplatifomu zokubeka iliso, kunye ne-cabling eyakhiweyo-ihlanganiswe kwangaphambili kwaye ivavanywe kwi-factory, eyenza ukuhanjiswa kweyona nto yokwenene. Oku kunciphisa kakhulu umsebenzi wokwakha kwindawo kwaye ixhasa ukukhutshwa kwenkonzo ngokukhawuleza.
Uyilo luvumela uhlengahlengiso olubanzi olusekwe kwiimfuno zabathengi kwaye luyakwazi ukuziqhelanisa noluhlu olubanzi lweemeko zesicelo esikhethekileyo.
● Ubunjineli obulungiselelweyo
Ixhaswa yi-R&D eyomeleleyo kunye nobuchule bokuvelisa, sibonelela ngamaziko edatha ekhonteyina alungelelanisiweyo. Iinketho ziquka amanqanaba okufumaneka kwenkqubo, amabakala okukhusela, imilinganiselo yesikhongozeli, imigangatho yamandla, iindlela zokupholisa, kunye nezinye iimfuno ezikhethekileyo zobugcisa.
● Ukusasazwa ngokukhawuleza
Zonke ii-subsystems ezibalulekileyo-i-UPS kunye nokuhanjiswa kwamandla, iiyunithi zokupholisa, ii-racks ze-IT, kunye ne-wiring-zihlanganiswe ngokupheleleyo ngaphakathi kwesitya ngaphambi kokunikezelwa. Ekubeni onke amacandelo acwangcisiwe kwaye avavanywe kwangaphambili, ukufakela kwisayithi kuba lula, kuvumela ukuhanjiswa kweprojekthi kwiintsuku nje ze-40.
● Ukhuseleko oluPhezulu kunye nokuthembeka
Izikhongozeli eziqhelekileyo zibonelela ngokhuseleko lwe-IP55, kunye neendlela zokuphucula kwi-IP65. Izixhasi ezongezelelweyo zibandakanya unyango lokuchasana nomhlwa, ukuxhathisa umlilo, ukuthintela ukuqhuma, kunye nokhuseleko lwebhola. Ucutho lomlilo olakhelwe ngaphakathi, ulawulo lofikelelo, kunye nokhuseleko lokubeka iliso kwividiyo ngokuchasene neengozi zomlilo, ubusela, kunye nofikelelo olungagunyaziswanga.
● Ukusebenza ngokuqhubekayo
Ngokukhuselwa okusingqongileyo okunamandla kunye noyilo oluphezulu olufumaneka kuzo zombini iinkqubo zamandla kunye nokupholisa, isisombululo siqinisekisa ukusebenza okuzinzile kunye nokungaphazamiseki kwiinkqubo zoshishino ezibalulekileyo zemishini.
| Konke kwiSisombululo esinye | |||
| 10ft IKhabhinethi | 20ft IKhabhinethi | 40ft IKhabhinethi | IiKhabhinethi zeModyuli yesiko |
![]() | ![]() | ![]() | ![]() |
| Isisombululo seDual Bay | |||
![]() | |||
| Multi Containers Solution | |||
![]() | |||
(1) Ukwakhiwa komgqomo
● Yenziwe ngokwemigangatho yesikhongozeli se-ISO
● Ukumelana nokutshizwa kwetyuwa: iiyure ezingama-750
● Ukugqunywa kwe-thermal yoboya bamatye
● Ukumelana nesantya somoya ukuya kuthi ga kwi-30 m/s
● Iinketho zokumelana nomlilo ukuya kwimizuzu eyi-120
● Ukukhuselwa kwebholastiki ngokuzikhethela kwiindawo ezinokhuseleko oluphezulu
● I-C5M ekwaziyo ukumelana nomhlwa kwindalo eselunxwemeni
● IP55 ukukhuselwa kothuli namanzi
● Ubushushu bokusebenza: -40°C ukuya +55°C
(2) Inkqubo yokuPholisa echanekileyo
● 5–31.5 kW ukupholisa okufakwe eludongeni (okuqhelekileyo)
● 6–90 kW iinketho zokupholisa ezikuluhlu
● 5–122.9 kW iinketho zokupholisa igumbi
● Ilungele amaqondo obushushu ukuya kutsho kuma-55°C
● Ulungelelwaniso olwahlukeneyo lokupholisa simahla olukhoyo
(3) IT Rack System
● I-1800 kg umthamo womthwalo omileyo
● 600/800 mm ububanzi; Iinketho zobunzulu be-1100/1200 mm
● Isithintelo sepaseji eshushu/ebandayo
● Iireyili zokutyibilika ngaphambili/ngasemva ukwenzela ukulungiswa lula
● Ulawulo lofikelelo lokuzikhethela ukwenzela ukhuseleko olongeziweyo
(4) Inkqubo yaMandla ye-UPS
● 3–60 kVA i-UPS efakwe kwi-rack
● 60–200 kVA i-UPS yeemodyuli (i-rack mount)
● 250–600 kVA iimodyuli ze-UPS (umgangatho wokunyuka)
● 48 VDC abalungisa (60 A–1200 A)
● I-VRLA okanye ulungelelwaniso lwebhetri ye-lithium-ion
● Ukhetho olusisiseko okanye oluhlakaniphile lwePDU
● Ukuhanjiswa kwamandla okwakhelwe ngaphakathi alungiselelwe amanqanaba exesha leTier I–IV
(5) Inkqubo yeDCIM
● Unxibelelwano olumanyeneyo kunye ne-UPS, ukupholisa, iimodyuli zamandla, kunye nezinzwa
● Ulawulo lofikelelo oludibeneyo
● Ucupho oludibeneyo lwevidiyo
● Ujongano lwescreen esichukumisayo sendawo (10/21/42 intshi)
● Ukufikelela kude ngewebhu, i-SMS, i-imeyile, i-Modbus-TCP; SNMP ekhethiweyo
(6) Inkqubo yoLawulo lokuFikelela
● IP55 indlela yokufikelela ezintathu-kwinye: Ikhowudi ye-PIN / igama lokugqitha / umnwe
● Ulawulo lwesoftware oluzimeleyo
● Idityaniswe ngokupheleleyo neqonga leDCIM
(7) Inkqubo yoKhuseleko loMlilo
● Ukufunyaniswa komlilo kwangethuba
● Iphaneli yomlilo ekrelekrele yolawulo olulula
● Iinketho ze-arhente yokucima umlilo: I-Novec 1230 okanye i-FM200
● Ukumelana namanzi kunye nobungqina bokufuma
● Ukukhusela isitshizi setyuwa
● Ukuthintela ukungunda
● Ukufakwa komlilo kunye ne-thermal
● Ukhuseleko lwenyikima
● Ukuchasa ubusela kunye nesakhono sokumelana nokudubula